Plastek Water Chillers
|
|
|
|
Water-cooled Water
Chillers:
KT series water-cooled water chillers suitable for operating in an
ambient temperature of 35?C and above. This type of chillers offer
cooling capacity from 8,800 to 180,000 Kcal/hr. Designed with
efficiency and intelligent controls in mind, this series of high
performance water chiller is engineered with outstanding refrigerating
technology.
|
|
|
|
Air-cooled Water
Chillers:
YT series air-cooled water chillers offer low noise running and no
pollution, meeting environmental protection requirements due to no
cooling tower is required. This type of chillers offer cooling
capacity from 5,600 to 83,000 Kcal/hr. Combining maximum efficiency
and superior performance in one unit, the YT series water chillers are
easy to maintain and install.
Cooling Towers & Water Circulation Pumps:
These optional accessories are necessary for the water-cooled
chillers.
|
|
Dega Water Chillers
|
|
|
|
DEGA is proposing a
new industrial refrigeration unit for the water cooling of heating
process. The compressors are hemi-hermetic type, so can be always
repaired; for this reasons give to the machine a maximum guarantee and
reliability avoid the costs of machine stop.
|
|
|
|
The external frame is
manufactured in aluminium, especially built against corrosion and it
can be easily combined to other module. The radiators are generously
built to give a choice for the mounting of centrifugal or axial fans,
thus giving the client the opportunity to re-use the radiator hot air.
In other to save space, the exhaust (steam) has been deviated back in
to the water container. The outstanding features of this unit, is the
combination of the instruments and electrical design, specifically
created not solely for its looks, but mostly on its safety features.
A module unit con be obtained (optional) to be connected in paralled
to the cooling system.
|
|
Shini Water Chillers
|
|
|
|
Industrial Chiller
Features:
1. The Tube-in shell condenser is used for higher efficiency.
2. The main power isolator.
3. The high and low pressure gauges show the refrigerant pressure of
the system.
4. High/Low pressure safety relay protects the compressor.
5. Freeze protection valve is installed for compressor safety.
6. The proper three phase pump size matches your process flow and
pressure requirement.
7. Hot gas bypass valve can balance the load on the chiller to meet
the needs of the process.
8. The drying filter cleans and dries the refrigerant to protect the
system from moisture of other contaminants.
9. The scroll and semi-hermetic compressor in high efficiency and can
produce low noise.
10. Heavy-duty welded stainless steel tank with insulation for
rust-free and energy saving.
11. The tube-in-shell evaporator is used fir higher efficiency.
|
|
|
|
|